PERBEDAAN KUALITAS CITRA MRI LUMBAL SEKUEN T2 TSE FAT SATURATION WEAK DAN STRONG PADA KASUS HNP
Abstract
Fat Saturation has two modes, namely Weak Mode and Strong Mode, thus further research is needed to determine whether there is a difference in image quality between the two. This study aims to identify the difference in image quality between T2 TSE Fat Saturation Weak Mode and Strong Mode in lumbar MRI for cases of Herniated Nucleus Pulposus (HNP). Data collection was conducted from October to November 2024 at the Radiology Department of SMC Telogorejo Hospital using a Siemens 1.5T MRI scanner. A total of ten patient images were analyzed by calculating the Signal to Noise Ratio (SNR) values in the anatomical structures of the Bone Marrow, Intervertebral Disc, CSF, and Spinal Cord using Radian DICOM Viewer. Statistical analysis was performed using SPSS. The Wilcoxon test showed a significant difference only in the Bone Marrow anatomy (p < 0.05). No significant differences were found in the Intervertebral Disc, CSF, or Spinal Cord (p > 0.05). The Weak Mode also provided a faster scanning time, making it more recommended for lumbar MRI examinations in HNP cases, especially since its image quality is nearly equivalent to Strong Mode for most anatomical structures. This study indicates that there was no significant difference in the Intervertebral Disc anatomy, which is the primary location of HNP. Therefore, Weak Mode is more recommended as it offers greater patient comfort through shorter examination time.
References
2. Astari FM, Rasyid, Fatimah. Perbedaan Informasi Citra Diagnostik Antara Sekuen T2 TSE STIR Dan T2 TSE Dixon Pada Pemeriksaan MRI Lumbal Potongan Sagital Dengan Kasus Radiculopathy. J Radiogr Indones. 2018;1(1):52–60.
3. Ikhsanawati A, Tiksnadi B, Soenggono A, Hidajat NN. Herniated Nucleus Pulposus in Dr. Hasan Sadikin General Hospital Bandung Indonesia. Althea Med J. 2015;2(2):179–85.
4. Nasution SLR, Ermi Girsang, Siti Aminah. a Comparative Study of Physiotherapy Outcomes Between Infrared-Tens Combination and Pnf Therapies in Nph Patients. J Vocat Heal Stud. 2025;8(3):191–9.
5. Pandoyo DA, Fajarini ES. Acceleration Factor GRAPPA terhadap Kualitas Citra MRI Sagittal T2 Lumbal pada Klinis Hernia Nucleus Pulposus. 2024;6(3):547–56.
6. Dalto V, Assad RL, Crema M, Louzada-Junior P, Nogueira-Barbosa M. MRI assessment of bone marrow oedema in the sacroiliac joints of patients with spondyloarthritis: is the SPAIR T2w technique comparable to STIR? Eur Radiol. 2017 Feb 6;27.
7. Agrilian MP, Tarigan A, W ME, Sari G. Penggunaan T2 STIR dan Fat Saturation pada Pemeriksaan MRI Lumbal Kasus Hernia Nucleus Pulposus (HNP). J Imejing Diagnostik. 2023;9(1):24–8.
8. Nuha M, Prasetya L, Dharmawan B. PERBEDAAN INFORMASI CITRA ANATOMI PADA PEMERIKSAAN MRI LUMBAL T2WI TSE FAT SATURATION DAN T2WI TSE DIXON POTONGAN SAGITAL PADA KLINIS HERNIA NUCLEUS PULPOSUS DI RSUP PROF Dr I GOESTI NGOERAH GDE NGOERAH DENPASAR. J Ris RUMPUN ILMU Kedokt. 2022 Oct 10;1:38–47.
9. Horger W, Kiefer B. Fat Suppression Techniques a Short Overview. 2011;57–8. Available from: www.siemens.com/magnetom-world
10. Brandão S, Seixas D, Ayres-Basto M, Castro S, Neto J, Martins C, et al. Comparing T1-weighted and T2-weighted three-point Dixon technique with conventional T1-weighted fat-saturation and short-tau inversion recovery (STIR) techniques for the study of the lumbar spine in a short-bore MRI machine. Clin Radiol. 2013 Nov;68(11):e617-23.
11. Guerini H, Omoumi P, Guichoux F, Vuillemin V, Morvan G, Zins M, et al. Fat Suppression with Dixon Techniques in Musculoskeletal Magnetic Resonance Imaging: A Pictorial Review. Semin Musculoskelet Radiol. 2015 Sep;19(4):335–47.
12. Ugwuanyi DC, Sibeudu TF, Irole CP, Ogolodom MP, Nwagbara CT, Ibekwe AM, et al. Evaluation of common findings in brain computerized tomography (CT) scan: A single center study. AIMS Neurosci. 2020;7(3):311–8.
13. Pramana K, Jeniyanthi N, Dharmawan I. PENGARUH PENGGUNAAN PARAMETER NUMBER SCAN AVERAGE TERHADAP SIGNAL TO NOISE RATIO DAN SCAN TIME PADA PEMERIKSAAN MAGNETIC RESONANCE IMAGING: STUDI LITERATURE REVIEW. JRI (Jurnal Radiogr Indones. 2022 May 29;5:48–53.
14. Del Grande F, Santini F, Herzka DA, Aro MR, Dean CW, Gold GE, et al. Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System. RadioGraphics [Internet]. 2014 Jan 1;34(1):217–33. Available from: https://doi.org/10.1148/rg.341135130
15. Zul Fikra, I Made Lana Prasetya, Hendra Setiawan. Peranan Sekuen Stir Pada Pemeriksaan MRI Shoulder Dengan Klinis Supraspinatus Injury Di Instalasi Radiologi Rumah Sakit Umum Pusat Persahabatan Jakarta Timur. J Ris Rumpun Ilmu Kedokt. 2023;2(2):198–208.
16. Adigun OO, Al-Dhahir MA. Anatomy, Head and Neck: Cerebrospinal Fluid. In Treasure Island (FL); 2025.
17. Harrow-Mortelliti M, Reddy V, Jimsheleishvili G. Physiology, Spinal Cord. In Treasure Island (FL); 2025.
18. Rusmayanti MY, Kurniawan SN. Hnp Lumbalis. JPHV (Journal Pain, Vertigo Headache). 2023;4(1):7–11.
Copyright (c) 2025 Alan Samudra, Hernastiti Sedya Utami, Lutfatul Fitriana, Fani Gimnastiar, Dea Zalfa Cahyla Adi, Muhamad Andin Dwi Pranata

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.





